RimwardCamera coverage review
01 · Site A · 14 ha · 12 MWp
3 of 9 cameras need action before a pilot.
The north fence is out of view, the north-east corner is too dark at night, and the substation view is missing.
- 3 priorities
- 2 other image-quality findings
- 4 cameras clear, day and night
- View gap
- Image limitation
- No view supplied
Each fence stretch shows its worst state, by day or at night. Schematic plan with indicative view directions. No detection range is implied.
02
Priorities before a pilot
North fence: expected here, outside the frame1C-05 · North fence
Check C-05’s north fence view
Day: View gapNight: View gap
- What we saw
- The supplied frame looks toward the panels. The north fence it should cover is outside the view. Seen in supplied views
- Not yet verified
- Whether the camera was moved or installed this way.
- Next action
- Confirm orientation and provide fresh day and night views.
- Suggested owner
- Installer
- Done when
- New views show the agreed fence stretch. Detection still needs a live test.
Source: Night still C05-N1 · site plan
Target zone: fence corner, not visible2C-02 · North-east corner
Verify C-02’s night visibility
Day: Area visibleNight: Image limitation
- What we saw
- The day view covers the corner. At night, only the nearest post is visible; the corner and fence beyond are lost in darkness. Seen in supplied views
- Not yet verified
- The cause: infrared, lighting or camera settings.
- Next action
- Check illumination and settings before choosing a fix.
- Suggested owner
- Installer
- Done when
- A new night view shows usable detail in the target zone.
Source: Night still C02-N1 · day still C02-D1
3C-08 · Substation
Obtain the substation views
Day: No view suppliedNight: No view supplied
- What we saw
- No view was supplied. On the call, the site team said a camera watches the transformer. Reported on the call
- Not yet verified
- What the camera sees, by day or by night.
- Next action
- Request images covering the transformer and cable access.
- Suggested owner
- Asset manager
- Done when
- Day and night images received and reviewed.
Source: First call, 4 Nov
03
Other findings
Far posts: softC-04 · West fence
Day: Image limitationNight: Image limitation
Both views are soft beyond the middle of the fence. Posts at the far end blur together.
Check focus and lens at the next maintenance visit. Installer · New views show the far posts in focus.
Far third: glare from road lightingC-07 · East fence
Day: Area visibleNight: Image limitation
At night, road lighting outside the site washes out the far third of the fence.
Review a night view taken after 01:00 before changing camera settings. Installer · A night view shows the far end of the fence without glare.
Area visible, day and night
- C-01 Main gate
- C-03 Inverter station
- C-06 South fence
- C-09 South-west corner
No action from this review. Detection is tested in a pilot.
04
Recommended next steps
Review the priority views, then agree a pilot that tests detection, evidence delivery and operator review on defined areas.
- Fix the priority issuesC-05 orientation and C-02 night visibility, with the installer.
- Send the missing viewsDay and night images from C-08 at the substation.
- Agree a paid pilotDefined cameras and areas, with clear tests for detection and alert delivery.